SMAART Suite New License (v9) - perpetual
SMAART Suite New License (v9) - perpetual
SMAART Suite New License (v9) - perpetual
SMAART Suite New License (v9) - perpetual
SMAART Suite New License (v9) - perpetual
SMAART Suite New License (v9) - perpetual
SMAART Suite New License (v9) - perpetual SMAART Suite New License (v9) - perpetual SMAART Suite New License (v9) - perpetual SMAART Suite New License (v9) - perpetual SMAART Suite New License (v9) - perpetual SMAART Suite New License (v9) - perpetual

SMAART

SMAART Suite New License (v9) - perpetual

ŠIFRA PROIZVODA: v9ST-PRP

The minimum system requirements for the Smaart v9 platform have changed from Smaart v8. Please read the requirements below carefully to ensure that v9 is compatible with your system. 

Minimum Req.Windows macOS
OS VersionWindows 10 (64-bit only)macOS 10.14 (Mojave)
Processor / CPU6th gen Intel Core i5 or similar/newer*6th gen Intel Core i5 or similar/newer
Any Apple Silicon M series
Memory / RAM4GB4GB
GraphicsHardware supporting DirectX 12**Any
Display1024 x 7681024 x 768
SoundASIO® or WAV/WDM driversCore Audio drivers

Note: Minimum requirements are established to ensure good performance when default settings are used. Consider a more powerful computer if you plan to use large FFT sizes or run many measurements simultaneously.

*Smaart does not support “Windows on ARM”

**Must support Feature Level 12 / WDDM 2.0+

Upgrades - dostupno na upit

1115.00 €

Fiksni tečaj konverzije: 1 € = 7,53450 kn

Za sve naše veleprodajne kupce unutar Zagrebačke županije vršimo BESPLATNU DOSTAVU na Vaš kućni prag !!!

iznad 66,36 € (500 Kn) dostava je besplatna na području CIJELE HRVATSKE!

Specifikacije proizvoda

KATEGORIJA
  • Studio
  • Software za studio
  • SMAART
DIMENZIJE

š: x v: x d: x m: kg

TAGOVI

Smaart

SPECIFIKACIJE

RTA

  • Unlimited simultaneous RTA measurements and live average of RTA data
  • Fractional-Octave banding up to 1/48th octave resolution
  • Fractional Octave or Line view of RTA data
  • View data as banded, lines, or both simultaneously
  • View Peak Holds, Target Curve (including cinema X-curves), and THD
  • Accurately display SPL levels per 1 and 1/3 octave bands with calibrated inputs
  • A, C, X, and Inverse weighting options for live and stored data
  • Fast, Slow, & Infinite data averaging selections, plus “none”

Spectrograph

  • Spectrum-over-time with amplitude represented by color
  • User definable dynamic range
  • Scrollable line history
  • Adjustable slice height resolution
  • Full color or grey scale

Real Time Mode: Transfer Function (dual channel)

  • Magnitude, Coherence, Phase, Live Impulse Response (Live IR) graphs
  • Unlimited simultaneous TF measurement and live average of TF engines
  • MTW and single-size FFT data acquisition from 128-128K
  • Up to 1/48th oct smoothing for magnitude and phase graphs
  • Reference delay finder with frequency filtering
  • Automatic reference delay tracking
  • Progressive averaging selections of 1-10, plus infinite.
  • A, C, X, and Inverse weighting options for live and stored data
  • Supports AES-75

Impulse Response Mode (IR Mode)

  • Linear, Logarithmic, Energy Time Curve, Spectrogram, Frequency, and Histogram graphs
  • Unlimited simultaneous IR measurement
  • Single and Dual channel IR measurement capability
  • Single time window FFT selections from 128-512k
  • Schroeder Reverse Integration curve for RT60 and EDT calculation
  • Speech intelligibility criterion including CIS, STI, and STIPA
  • Supports Noiseless and Noise Present STI calculation
  • Automatic calculation of octave and 1/3 octave filter band passes
  • User-definable frequency bandpass
  • All-Bands table view for all acoustical values

SPL (Sound Pressure Level)

  • Monitoring and Logging of an unlimited number of calibrated inputs
  • SPL A, C, & Unweighted Fast and Slow
  • Peak C, Peak Z (unweighted), Peak A, and Peak Octave banded frequency
  • Leq A, C, unweighted, and Octave band with user definable time-period from 1sec-24 hours.
  • C-A ratio calculation
  • OHSA and NIOSH exposure calculation
  • L10, L50, L90 calculation
  • 10 EaZy integration for Class 1 or Class 2 compliant SPL measurement
  • 10 EaZy Maximum Average Meter display
  • User definable SPL grid display
  • SPL History Display
  • User definable Alarms and ‘traffic light’ meter display colors
  • Remotely view actively logging inputs from a web browser via LAN
  • PDF reports with customizable reporting selection.
  • Email reports straight from Smaart

Signal Generator

  • Multi-output; mono, multi-mono, stereo
  • Independent output trim
  • 10 programmable output presets
  • Random, Pseudorandom, SMPTE, and speech weighted noise
  • Sine, Sweep, File playback (.WAV .AIFF), and new Pink Sweep (swept sine)
  • Optional noise fade-in

Data Acquisition and Manipulation

  • Unlimited simultaneous input and output channels
  • Unlimited tabs and windows
  • ASIO, Wav, and CoreAudio driver support
  • Input calibration for SPL
  • Integrated gain and phantom power control with gain tracking for the Roland OctaCapture
  • 10 EaZy hardware integration for Class 1 or Class 2 measurement
  • Capture, store, and organize measurement data directly within Smaart
  • ASCII Import, Export, and Copy functions for captured data
  • Client Window - remotely view and capture Real-Time Data